C7108KIT Instructions
Instructions for cleaning the handspray for the A360-6 and A1679-6 faucet with sidespray - C7108 |
The handspray is a simple on-off system. If it is leaking, or stays on, there is probably dirt in the mechanism. |
Preparation
|
Filter Cleaning (Black Faceplate) |
|
1. Unscrew the faceplate. ATTENTION: Turn the water off to service the handspray. |
2. Push the button and unthread the filter. |
Clean or Replace the Internal Cartridge |
|
1. Unscrew the spray head. ATTENTION: Turn the water off to service the handspray. |
2. Separate the head from the handle without unthreading the tube. |
3. Unscrew the faceplate. |
4. Push the button and unthread the filter and internal cartridge. |
Clean or Replace the Back Flow Preventer |
|
1. Disconnect the flexible hose from the shower. ATTENTION: Turn the water off to service the handspray. |
2. Unscrew the spray head. |
3. Unthread the tube from the handle. |
4. With the help of the tube, unthread the back flow preventer. |
Spare Parts |
|||
![]() |
|||
Disassembling Button
|
![]() |