9.07245 Diverter Instructions

PERRIN & ROWE® DIVERTER O-RING SET FOR 4 HOLE 
DECK MOUNTED TUB SET 9.07245
 
 
Tools Required

4mm Allen key (comes with diverter kit), pliers or channel lock & small slotted screwdriver.

 

Preparation:

Shut water supply to the faucet off: Important: Turn off the water supply at the faucet before starting. You can either turn off the main supply to the house or close the shut-off valves if the faucet is equipped with them. Then open the faucet again to empty it of residual water. Failure to do so could result in flooding or injury. 

clipboard_e69e0f61012fd9730782a457a4109087d.png

Snag_6d41c9a.png

1. Remove pop-up knob from diverter rod. Pull up on the knob, and while holding the rod, unscrew the knob by rotating counterclockwise by hand.

Snag_6d42554.png

2. Using a 4mm Allen key, remove the set screw on the back side at the base of the spout by rotating counterclockwise.

Snag_6d6adb4.png

3. Pull the spout off the rough body using upward force by hand.

Snag_6d6cb7d.png

4. Using channel lock, unscrew brass top (Tip: Put the channel lock in the open holes on top of the rough).

Snag_6d793af.png

5. Pull the brass top off to remove diverter rod and plunger.

Snag_6d7ccff.png

6. Replace the O-ring, spring, diverter disk, and screw.

7. After replacing the parts in number six, do the steps in reverse, then test

 