Skip to main content
House of Rohl Solutions

R9261912 - R7903 Cartridge Replacement

Preparation:

Tools needed:

  • 3 mm Allen key
  • Pliers/Channel locks
  • 38 mm Wrench/Pipe wrench

 Shut water supply to the faucet off: Important: Turn off the water supply at the faucet before starting. You can either turn off the main supply to the house or close the shut-off valves if the faucet is equipped with them. Then open the faucet again to empty it of residual water. Failure to do so could result in flooding or injury. 

clipboard_e2ef9faf0dde14236398e708fb4dbc2f8.png

Snag_17c9206.png

Instruction to remove Cartridge:

2. Unscrew the handle.

Snag_669fe76.png

3. Unscrew the brass bolt with a pair of Pliers

Snag_66a76b4.png

4. Use 3mm Allen key to remove 5. Unscrew dome to expose cartridge nut handle. Do NOT remove screw

Snag_66bbdab.png

5. Unscrew dome to expose cartridge nut

Snag_66cd5d1.png

6. Use 38mm wrench or pipe wrench to remove cartridge

Snag_66e1f49.png

7. Remove the cartridge from the body of the faucet.            

       Snag_66f7748.png

8. Place the 3 new o-rings into the body

Snag_66fc5f4.png

 9. Reverse the steps to replace the new cartridge and test the unit.

 

Contact Us:

Canadian ConsumersEmail or Call 1-866-473-8442

U.S. ConsumersEmail or Call 1-800-777-9762

clipboard_ebadcac026e4b2305fc6e23bf5470d8c9.png
  • Was this article helpful?