Quick-connect 7798 cleaning
This article explains the steps to remove and clean the 7798 quick connect for low flow issue |
|
Preparation: |
Important: Turn off the water supply at the faucet before starting. You can either turn off the main supply to the house or close the shut-off valves if the faucet is equipped with them. Then open the faucet again to empty it of residual water. Failure to do so could result in flooding or injury.
- Recommended tools: Adjustable wrench, hook or needle-nose pliers
Instructions: |
Hold down (A) and pull down the hose (B) |
|
Clean the check valve and/or flow restrictor. Follow the step in reverse to reinstall the check valve. |
|